STRAMIT CAPACITYPLUS™

Home / Products Gallery / Roofing & Wall Cladding / Stramit CapacityPLUS

SELECTION & SPECIFICATION

FEATURES:

Stramit CapacityPlus
  • High 50mm ribs – excellent water-carrying capacity at low roof pitch and superior profile rigidity.

  • Simple rib shape – enables reliable screw fixing, and easy to trim and notch flashings.

  • Wide 810mm cover – fewer sheets enabling fast handling and laying, and cost economy.

  • Screw fixed – allows fast and flexible high-wind installation techniques such as ‘tack and screw-off’.

  • Range of materials – choice of materials and finishes for enhanced durability options.

  • Low 1o pitch – building economies due to low wall heights and structure reduction.

  • Fully tested – in-house and independent testing for reliable design data and peace-of-mind.

  • Nesting profile – flat packs for economical transport and site crane handling.

APPLICATIONS:

The drainage capacity, strength, wide cover, light weight and weather resistance of Stramit CapacityPLUS™ cladding make it perfect for large commercial roofing and walling applications. Its excellent strength and ease of assembly allow for long, economical spans. The large water-carrying capacity and weather-tightness permit very low roof pitches, leading to economies in the building structure.

Stramit CapacityPLUS™ cladding is only intended for use in commercial/industrial roof and wall cladding applications. Do not use for any other purpose.

MATERIALS:

Stramit CapacityPLUS™ cladding can be supplied in coated and coloured high strength steel, stainless steel and aluminium.

Coated steel product is manufactured from high yield strength G550 colour coated steel or zinc aluminium-alloy coated steel. In some locations galvanised and severe environment colour coated steel may be available by arrangement. Colour coated steels are in accordance with AS2728 – Category 3 and, for the substrate, with AS1397. Zinc aluminium-alloy coated AZ150 and galvanised Z450 conform to AS1397.

Stramit has a comprehensive range of colours as standard. Ask at your nearest Stramit location for colour availability.

STRAMIT CapacityPLUS™ CLADDING -
SHEETING MASS (kg/m2 of roof area)
Zincalume® Colorbond® Aluminium
0.42mm steel BMT 4.64 4.72 -
0.48mm steel BMT 5.27 5.35 -
0.7mm aluminium - - 2.54
0.9mm aluminium - - 3.26

ADVERSE CONDITIONS:

Stramit CapacityPLUS™ cladding will give excellent durability in almost all locations. It is however important to choose the correct coating for each application environment.

The table below shows the suitability of coating types for different exposure conditions.

STRAMIT CapacityPLUS™ CLADDING -
SHEETING MASS (kg/m2 of roof area)
Zincalume® Colorbond® Aluminium
0.42mm steel BMT 4.64 4.72 -
0.48mm steel BMT 5.27 5.35 -
0.7mm aluminium - - 2.54
0.9mm aluminium - - 3.26

suitability of
coating type
site exposure condition
benign moderate severe very severe
Zincalume® AZ150 ? ?
Colorbond® ?
Colorbond® Ultra N/A N/A ?

? Question marks indicate conditions where durability may be diminished, depending on the particular application.

The approximate site exposure conditions in the table above are defined below.

site exposure
condition
distance of site from
rough
active surf
calm, still
salt water
industrial
emission
fossil fuel
combustion
benign 1000m + 100m + 500m + 500m +
moderate 400m-1000m 0-100m 250m-500m 250m-500m
severe 100m-400m N/A 100m-250m 100m-250m
very severe 0-100m N/A 0-100m 0-100m

Note - The suitability and exposure tables above are guidelines only; conditions will vary from site to site. If in any doubt about the choice of coating for a particular application consult your nearest Stramit office for advice.

COMPATIBILITY:

All building products need to be checked for compatibility with adjacent materials, whether they be part of the current project or pre-existing or planned building elements. These checks need to be for both direct contact between materials, and where water runs from one material to another.The following guidelines generally avoid material incompatibility:

  • For ZINCALUME®, COLORBOND® and galvanised roofs avoid copper, lead, green or treated timber, stainless steel and mortar or concrete.

  • In addition galvanised roofs should not receive drainage from aluminium, copper or any inert materials, such as plastics, glass, glazed tiles, COLORBOND® and ZINCALUME®. Contact Stramit for more detailed information.

TESTING:

Stramit has in-house, purpose built, testing equipment used to design, develop and improve products for the Australian market. In addition many Stramit® products are tested or witnessed by independent organisations.

These include:

  • Cyclone Testing Station (James Cook University)

  • The University of Sydney

  • University of Queensland

  • University of Technology, Sydney

This ongoing research and development activity ensures that Stramit remains at the forefront of innovation, design and consumer information.

ARCHITECTURAL SPECIFICATION:

This specification may be used to ensure that required performance and functional needs are met:-

The roofing/walling shall be Stramit CapacityPLUS™ cladding in continuous lengths with trapezoidal ribs approximately 50mm high, spaced at 270mm centres.

Sheeting material shall be:

  • 0.42mm or 0.48mm bmt G550 protected steel sheet to Australian Standard AS1397, with a minimum yield stress of 550MPa (Grade G550) and an AZ150 zincaluminium coating with or without an oven-baked paint film of selected colour.
    or

  • 0.7mm or 0.9mm cold-rolled aluminium sheet of alloy 3004 H34, 5152 H39 or 5052 H38, in accordance with AS2848 and AS1734 or profile manufacturer approved equivalent.

The sheeting shall be fixed to the purlins/girts in accordance with the manufacturer’s recommendations. Suitable fixing screws in accordance with Australian Standards AS3566, Class 3, shall be used at every rib at every support with side lap fasteners installed at mid span if required. A minimum of 50mm shall be provided for projection into gutters. Flashings shall be supplied in compatible materials as specified; minimum cover of flashing shall be 150mm. All sheeting shall be fixed in a workman-like manner, leaving the job clean and weathertight. Repair minor blemishes with touch-up paint supplied by the roof manufacturer. All debris (nuts, screws, cuttings, filings etc.) shall be cleaned off daily.

COMPANY DETAILS

Phone: 07 5439 0990
Fax: 07 5439 0770

Address:
26 Beerwah Parade
Beerwah, Sunshine Coast
QLD 4519, Australia

Postal Address:
PO BOX 147,
Mooloolaba, Sunshine Coast
QLD 4557, Australia

What’s New at Ascent

QBSA Lic: #1069230
NSW Lic: #187568C

REQUEST FOR QUOTE

Continue

COLORBOND COLOURS

Colorbond Colours